Conventional Control Panels
Designed and made
according to EN54 standards, the J400 series are a microprocessor control
panels for medium and large applications.
The available models are:
J408-2 (2 zone)
J408-4 (4 zone)
J408-8 (8 zone)
J424-8 (8 zone expandable to 24).
Accessories
J400-REP (repeater)
J400-EXT (extinguishment modules)
J400-LCD (display module)
J400-EXP8(expantion board)
ANALOGUE FIRE
CONTROL PANEL
The FIRE CLASS 100 is a programmable, modular control panel (EN54 Approved),
suitable for small to medium fire alarm systems. It has 1 analogue loop for
the connection of fire control devices (sensors, alarm buttons, sirens,
etc.), and a conventional controlled line. During the programming phase each
loop device can be assigned to 4 of the 16 available software zones, these
in turn, may be assigned to the 13 controlled and silenceable outputs
(relays), managed by the control panel (1 on the main board and 12 on the 2
FC200/6OUT output expanders, optional).
A fault output relay, non-controlled and non-silenceable is also provided.
Up to 8 FC200/REP annunciator panels (optional) with the same display and
fast key functions as the main panel, can be connected to the control panel
by 2 wires, using an RS485.
It is possible to program and manage the control panel from a PC via the
FC200/SW software application (optional).
The telephone features are supplied by the FC200/COM telecom module.
Power supply: 2.5 A switching supply/battery charger. |
|
|
|
|
|
ANALOGUE FIRE CONTROL PANEL
The FIRE CLASS 200 is a programmable, modular control panel, which meets the
EN54 standard, and is suitable for medium to large fire alarm systems. It
has 2 analogue loops for the connection of fire-control devices (sensors,
alarm buttons, sirens etc.), and a conventional controlled line. During the
programming phase, each line may be assigned to 4 of the 16 software zones,
which in turn, may be assigned to the 16 controlled and silenceable outputs
(relays), managed by the control panel (4 on the main board and 12 on 2
optional FC200/OUT output expanders). Each zone has a repeat output (open
collector) for selected intervention during alarm (location signalling,
closing of fire-barrier doors, etc.). An auxiliary alarm output and a
fault-signal output (relay), non-controlled and non-silenceable, are also
available. The control panel is protected by a lockable door with a
plexiglas front, and codes which allow command access to authorized
personnel only. Up to 8 FC200/REP annunciator panels (optional), with the
same display and fast-key functions as the main panel, can be connected to
the control panel by 2 wires by means of an RS485 bus. The optional FC200/SW
software makes it possible to program and manage the control panel from a
local PC (connected to the serial port on the control panel) or from a
remote PC connected via telephone by means of an optional FC200/COM Telecom
module, for teleservice. The Telecom module manages the most widely used
communication